Skip to main content

Server & Workstation Storage, NVMe, PCIe and CPU Platform Configuration Reference

Scope and methodology. This reference covers 96 chassis/backplane configurations across TekBoost’s actively orderable refurbished server and workstation catalogue — Dell PowerEdge (13th and 14th Generation), HPE ProLiant (Gen9 and Gen10), Dell Precision Tower, and HP Z Workstation. The figures below are TekBoost’s own orderable configure-to-order (CTO) platform data — the same data our configurators use to compute what you can select and check out with today — not a transcription of manufacturer marketing copy. They represent TekBoost’s currently orderable configuration options, which are a subset of a platform’s full theoretical manufacturer capability in some cases.

What this does not cover. GPU power-draw (TDP) figures are not included — our underlying data does not currently carry reliable per-chassis GPU TDP figures, and we would rather omit that column than publish a placeholder. Memory (DIMM) configuration data is intentionally not part of this asset; see a given model’s own hub page for verified memory specifications. Pricing is not shown.

One data note, for transparency: the R730XD-24SFF-4xNVME configuration’s underlying record lists an NVMe drive quantity but does not separately flag “NVMe” among its listed drive interfaces — the NVMe quantity itself is correct and reflects what the configurator supports; the interface list for that one row is a minor labeling inconsistency in our source data, noted here rather than silently smoothed over.

Last verified: September 21, 2026, directly against TekBoost’s live configurator data.

Part 1 — Storage, drive-bay and NVMe configuration reference

Dell PowerEdge

Chassis / config Form factor Max drives Max NVMe (native) Max M.2 native Drive interfaces supported
R740XD-24SFF SFF 24 — — SATA,SAS
R740XD-24SFF-FlexBay SFF 28 — — SATA,SAS
R740XD-24SFF-12xNVME SFF 24 12 — SATA,SAS,NVMe
R740XD-24SFF-24xNVME SFF 24 24 — SATA,SAS,NVMe
R740XD-12LFF SFF,LFF 12 — — SATA,SAS
R740XD-14LFF SFF,LFF 14 — — SATA,SAS
R740XD-16LFF SFF,LFF 16 — — SATA,SAS
R740XD-18LFF SFF,LFF 18 — — SATA,SAS
R740-8SFF SFF 8 — — SATA,SAS
R740-16SFF SFF 16 — — SATA,SAS
R740-8LFF SFF,LFF 8 — — SATA,SAS
R640-8SFF SFF 8 — — SATA,SAS
R640-10SFF SFF 10 — — SATA,SAS
R640-10SFF-4xNVME SFF 10 4 — SATA,SAS,NVMe
R640-10SFF-8xNVME SFF 10 8 — SATA,SAS,NVMe
R640-10SFF-10xNVME SFF 10 10 — SATA,SAS,NVMe
R540-8LFF SFF,LFF 8 — — SATA,SAS
R540-12LFF SFF,LFF 12 — — SATA,SAS
R440-4LFF SFF,LFF 4 — — SATA,SAS
R440-8SFF SFF 8 — — SATA,SAS
R440-10SFF SFF 10 — — SATA,SAS
T340-8LFF SFF,LFF 8 — — SATA,SAS
T440-8LFF SFF,LFF 8 — — SATA,SAS
T440-16SFF SFF 16 — — SATA,SAS
T640-8LFF SFF,LFF 8 — — SATA,SAS
T640-18LFF SFF,LFF 18 — — SATA,SAS
T640-16SFF SFF 16 — — SATA,SAS
T640-32SFF SFF 32 — — SATA,SAS
R730XD-24SFF SFF 24 — — SATA,SAS
R730XD-24SFF-4xNVME SFF 24 4 — SATA,SAS
R730XD-12LFF SFF,LFF 12 — — SATA,SAS
R730-8SFF SFF 8 — — SATA,SAS
R730-16SFF SFF 16 — — SATA,SAS
R730-8LFF SFF,LFF 8 — — SATA,SAS
R630-8SFF SFF 8 — — SATA,SAS
R630-10SFF SFF 10 — — SATA,SAS
R630-10SFF-4xNVME SFF 10 4 — SATA,SAS
R530-8LFF SFF,LFF 8 — — SATA,SAS
R430-8SFF SFF 8 — — SATA,SAS
R430-10SFF SFF 10 — — SATA,SAS
R430-4LFF SFF,LFF 4 — — SATA,SAS
T630-8LFF SFF,LFF 8 — — SATA,SAS
T630-18LFF SFF,LFF 18 — — SATA,SAS
T630-16SFF SFF 16 — — SATA,SAS
T630-32SFF SFF 32 — — SATA,SAS
T430-8LFF SFF,LFF 8 — — SATA,SAS
T430-16SFF SFF 16 — — SATA,SAS
T330-8LFF SFF,LFF 8 — — SATA,SAS

HPE ProLiant

Chassis / config Form factor Max drives Max NVMe (native) Max M.2 native Drive interfaces supported
DL380G10-8SFF SFF 8 — — SATA,SAS
DL380G10-16SFF SFF 16 — — SATA,SAS
DL380G10-24SFF SFF 24 — — SATA,SAS
DL380G10-8SFF-2xNVMe SFF 8 2 — SATA,SAS,NVMe
DL380G10-8SFF-8xNVMe SFF 8 8 — SATA,SAS,NVMe
DL380G10-16SFF-2xNVME SFF 16 2 — SATA,SAS,NVMe
DL380G10-16SFF-8xNVME SFF 16 8 — SATA,SAS,NVMe
DL380G10-16SFF-16xNVME SFF 16 16 — SATA,SAS,NVMe
DL380G10-24SFF-8NVME SFF 24 8 — SATA,SAS,NVMe
DL380G10-24SFF-16NVME SFF 24 16 — SATA,SAS,NVMe
DL380G10-24SFF-24NVME SFF 24 24 — SATA,SAS,NVMe
DL380G10-8LFF SFF,LFF 8 — — SATA,SAS
DL380G10-12LFF SFF,LFF 12 — — SATA,SAS
DL360G10-8SFF SFF 8 — — SATA,SAS
DL360G10-8SFF-2xNVME SFF 8 2 — SATA,SAS,NVMe
DL360G10-10SFF SFF 10 — — SATA,SAS
DL360G10-10SFF-2xNVME SFF 10 2 — SATA,SAS,NVMe
DL360G10-10SFF-8xNVME SFF 10 8 — SATA,SAS,NVMe
DL360G10-10SFF-10xNVME SFF 10 10 — SATA,SAS,NVMe
DL360G10-4LFF SFF,LFF 4 — — SATA,SAS
ML350G10-8SFF SFF 8 — — SATA,SAS
ML350G10-16SFF SFF 16 — — SATA,SAS
ML350G10-8LFF SFF,LFF 8 — — SATA,SAS
DL380G9-8SFF SFF 8 — — SATA,SAS
DL380G9-16SFF SFF 16 — — SATA,SAS
DL380G9-24SFF SFF 24 — — SATA,SAS
DL360G9-8SFF SFF 8 — — SATA,SAS
DL360G9-10SFF SFF 10 — — SATA,SAS
DL360G9-4LFF SFF,LFF 4 — — SATA,SAS
ML350G9-8SFF SFF 8 — — SATA,SAS
ML350G9-16SFF SFF 16 — — SATA,SAS
ML350G9-8LFF SFF,LFF 8 — — SATA,SAS

Dell Precision Tower

Chassis / config Form factor Max drives Max NVMe (native) Max M.2 native Drive interfaces supported
T3660-12G SFF,LFF 4 — 3 SATA,M.2,SSD
T3660-13G SFF,LFF 4 — 3 SATA,M.2,SSD
T3680-13G SFF,LFF 4 — 3 SATA,M.2,SSD
T3680-14G SFF,LFF 4 — 3 SATA,M.2,SSD
T5820-W21 SFF,LFF 4 — — SATA,SSD
T5820-W22 SFF,LFF 4 — — SATA,SSD
T5820-X SFF,LFF 4 — — SATA,SSD
T7920 SFF,LFF 4 — 2 SATA,M.2,SSD
T5860 SFF,LFF 4 — 2 SATA,M.2,SSD

HP Z Workstation

Chassis / config Form factor Max drives Max NVMe (native) Max M.2 native Drive interfaces supported
Z4G4-W1 SFF,LFF 2 — — SATA,SSD
Z4G4-W2 SFF,LFF 2 — — SATA,SSD
Z4G4-X SFF,LFF 2 — — SATA,SSD
Z6G4-CTO SFF,LFF 2 — — SATA,SSD
Z8G4-CTO SFF,LFF 4 — — SATA,SSD
Z2G9-MT-12G SFF,LFF 2 — 3 SATA,M.2,SSD
Z2G9-MT-13G SFF,LFF 2 — 3 SATA,M.2,SSD

Part 2 — PCIe expansion and CPU platform reference

Dell PowerEdge

Chassis / config Max PCIe adapter slots CPU sockets (min–max) Supported CPU platform(s)
R740XD-24SFF 8 1–2 X-Scalable
R740XD-24SFF-FlexBay 4 1–2 X-Scalable
R740XD-24SFF-12xNVME 6 2 X-Scalable
R740XD-24SFF-24xNVME 6 2 X-Scalable
R740XD-12LFF 8 1–2 X-Scalable
R740XD-14LFF 3 1–2 X-Scalable
R740XD-16LFF 8 1–2 X-Scalable
R740XD-18LFF 3 1–2 X-Scalable
R740-8SFF 7 1–2 X-Scalable
R740-16SFF 7 1–2 X-Scalable
R740-8LFF 7 1–2 X-Scalable
R640-8SFF 3 1–2 X-Scalable
R640-10SFF 3 1–2 X-Scalable
R640-10SFF-4xNVME 2 2 X-Scalable
R640-10SFF-8xNVME 2 2 X-Scalable
R640-10SFF-10xNVME 2 2 X-Scalable
R540-8LFF 3 1–2 X-Scalable
R540-12LFF 3 1–2 X-Scalable
R440-4LFF 2 1–2 X-Scalable
R440-8SFF 2 1–2 X-Scalable
R440-10SFF 2 1–2 X-Scalable
T340-8LFF 4 1 X-E2100,X-E2200
T440-8LFF 5 1–2 X-Scalable
T440-16SFF 5 1–2 X-Scalable
T640-8LFF 8 1–2 X-Scalable
T640-18LFF 8 1–2 X-Scalable
T640-16SFF 8 1–2 X-Scalable
T640-32SFF 8 1–2 X-Scalable
R730XD-24SFF 6 1–2 X-E5_2600_v3,X-E5_2600_v4
R730XD-24SFF-4xNVME 5 1–2 X-E5_2600_v3,X-E5_2600_v4
R730XD-12LFF 6 1–2 X-E5_2600_v3,X-E5_2600_v4
R730-8SFF 7 1–2 X-E5_2600_v3,X-E5_2600_v4
R730-16SFF 7 1–2 X-E5_2600_v3,X-E5_2600_v4
R730-8LFF 7 1–2 X-E5_2600_v3,X-E5_2600_v4
R630-8SFF 3 1–2 X-E5_2600_v3,X-E5_2600_v4
R630-10SFF 3 1–2 X-E5_2600_v3,X-E5_2600_v4
R630-10SFF-4xNVME 2 1–2 X-E5_2600_v3,X-E5_2600_v4
R530-8LFF 5 1–2 X-E5_2600_v3,X-E5_2600_v4
R430-8SFF 2 1–2 X-E5_2600_v3,X-E5_2600_v4
R430-10SFF 2 1–2 X-E5_2600_v3,X-E5_2600_v4
R430-4LFF 2 1–2 X-E5_2600_v3,X-E5_2600_v4
T630-8LFF 7 1–2 X-E5_2600_v3,X-E5_2600_v4
T630-18LFF 7 1–2 X-E5_2600_v3,X-E5_2600_v4
T630-16SFF 7 1–2 X-E5_2600_v3,X-E5_2600_v4
T630-32SFF 7 1–2 X-E5_2600_v3,X-E5_2600_v4
T430-8LFF 5 1–2 X-E5_2600_v3,X-E5_2600_v4
T430-16SFF 5 1–2 X-E5_2600_v3,X-E5_2600_v4
T330-8LFF 3 1 X-E3_1200_v5,X-E3_1200_v6

HPE ProLiant

Chassis / config Max PCIe adapter slots CPU sockets (min–max) Supported CPU platform(s)
DL380G10-8SFF 8 1–2 X-Scalable
DL380G10-16SFF 8 1–2 X-Scalable
DL380G10-24SFF 8 1–2 X-Scalable
DL380G10-8SFF-2xNVMe 8 2 X-Scalable
DL380G10-8SFF-8xNVMe 5 2 X-Scalable
DL380G10-16SFF-2xNVME 8 2 X-Scalable
DL380G10-16SFF-8xNVME 5 2 X-Scalable
DL380G10-16SFF-16xNVME 2 2 X-Scalable
DL380G10-24SFF-8NVME 5 2 X-Scalable
DL380G10-24SFF-16NVME 2 2 X-Scalable
DL380G10-24SFF-24NVME 0 2 X-Scalable
DL380G10-8LFF 8 1–2 X-Scalable
DL380G10-12LFF 8 1–2 X-Scalable
DL360G10-8SFF 3 1–2 X-Scalable
DL360G10-8SFF-2xNVME 3 2 X-Scalable
DL360G10-10SFF 3 1–2 X-Scalable
DL360G10-10SFF-2xNVME 3 2 X-Scalable
DL360G10-10SFF-8xNVME 1 2 X-Scalable
DL360G10-10SFF-10xNVME 1 2 X-Scalable
DL360G10-4LFF 3 1–2 X-Scalable
ML350G10-8SFF 8 1–2 X-Scalable
ML350G10-16SFF 8 1–2 X-Scalable
ML350G10-8LFF 8 1–2 X-Scalable
DL380G9-8SFF 6 1–2 X-E5_2600_v3,X-E5_2600_v4
DL380G9-16SFF 6 1–2 X-E5_2600_v3,X-E5_2600_v4
DL380G9-24SFF 6 1–2 X-E5_2600_v3,X-E5_2600_v4
DL360G9-8SFF 3 1–2 X-E5_2600_v3,X-E5_2600_v4
DL360G9-10SFF 3 1–2 X-E5_2600_v3,X-E5_2600_v4
DL360G9-4LFF 3 1–2 X-E5_2600_v3,X-E5_2600_v4
ML350G9-8SFF 9 1–2 X-E5_2600_v3,X-E5_2600_v4
ML350G9-16SFF 9 1–2 X-E5_2600_v3,X-E5_2600_v4
ML350G9-8LFF 9 1–2 X-E5_2600_v3,X-E5_2600_v4

Dell Precision Tower

Chassis / config Max PCIe adapter slots CPU sockets (min–max) Supported CPU platform(s)
T3660-12G 2 1 Core 12thGen
T3660-13G 2 1 Core 13thGen
T3680-13G 2 1 Core 13thGen
T3680-14G 2 1 Core 14thGen
T5820-W21 4 1 X-W2100
T5820-W22 4 1 X-W2200
T5820-X 4 1 Core 9thGen,Core 10thGen
T7920 7 1–2 X-Scalable
T5860 4 1 X-W2400

HP Z Workstation

Chassis / config Max PCIe adapter slots CPU sockets (min–max) Supported CPU platform(s)
Z4G4-W1 5 1 X-W2100
Z4G4-W2 5 1 X-W2200
Z4G4-X 5 1 Core 9thGen,Core 10thGen
Z6G4-CTO 6 1–2 X-Scalable
Z8G4-CTO 7 1–2 X-Scalable
Z2G9-MT-12G 4 1 Core 12thGen
Z2G9-MT-13G 4 1 Core 13thGen,Core 14thGen

How to use this reference

  • Planning NVMe capacity: compare the “Max NVMe (native)” column across configurations of the same base model — for example, the PowerEdge R640 is orderable from 0 up to 10 native NVMe bays depending on which 10SFF backplane configuration you choose.
  • Planning PCIe expansion: the “Max PCIe adapter slots” figure drops as NVMe backplane options increase on several platforms (notably the DL380 Gen10 and R640 families) — more NVMe bays generally means fewer general-purpose PCIe slots, because both draw from the same riser/lane budget. Check both columns together before finalizing a GPU, HBA or networking-card plan.
  • Matching CPU platform to workload: the “Supported CPU platform(s)” column shows which processor family a chassis is built around. Cross-reference with a model’s own hub page for full processor and memory detail.
  • These are TekBoost’s orderable options, not a ceiling on every possible configuration of a platform. If you need a configuration outside what’s listed, contact us with the model and requirements for a custom quote.

Related TekBoost resources